dwww Home | Manual pages | Find package

scanimage(1)             SANE Scanner Access Now Easy             scanimage(1)

NAME
       scanimage - scan an image

SYNOPSIS
       scanimage  [-d|--device-name  dev]  [--format format] [-i|--icc-profile
       profile]   [-L|--list-devices]   [-f|--formatted-device-list    format]
       [-b|--batch   [format]]  [--batch-start  start]  [--batch-count  count]
       [--batch-increment  increment]   [--batch-double]   [--accept-md5-only]
       [-p|--progress]  [-o|--output-file  path]  [-n|--dont-scan] [-T|--test]
       [-A|--all-options]   [-h|--help]    [-v|--verbose]    [-B|--buffer-size
       [=size]] [-V|--version] [device-specific-options]

DESCRIPTION
       scanimage  is a command-line interface to control image acquisition de-
       vices such as flatbed scanners or cameras.  The  device  is  controlled
       via  command-line  options.   After  command-line processing, scanimage
       normally proceeds to acquire an image.  The image data  is  written  to
       standard  output  in  one of the PNM (portable aNyMaP) formats (PBM for
       black-and-white images, PGM for grayscale images, and PPM for color im-
       ages),  TIFF  format (black-and-white, grayscale or color), PNG format,
       or JPEG format (compression level 75).  scanimage accesses image acqui-
       sition devices through the SANE (Scanner Access Now Easy) interface and
       can thus support any device for which there exists a SANE backend  (try
       apropos sane- to get a list of available backends).

EXAMPLES
       To get a list of devices:

         scanimage -L

       To scan with default settings to the file image.pnm:

         scanimage >image.pnm

       To  scan 100x100 mm to the file image.tiff (-x and -y may not be avail-
       able with all devices):

         scanimage -x 100 -y 100 --format=tiff >image.tiff

       To print all available options:

         scanimage -h

OPTIONS
       There are two sets of options available when running scanimage.

       The options that are provided by scanimage itself are listed below.  In
       addition, each backend offers its own set of options and these can also
       be specified. Note that the options available from the backend may vary
       depending on the scanning device that is selected.

       Often  options  that are similar in function may be implemented differ-
       ently across backends. An example of this difference is --mode Gray and
       --mode  Grayscale.  This may be due to differing backend author prefer-
       ences.  At other times, options are defined by the scanning device  it-
       self and therefore out of the control of the backend code.

       Parameters are separated by a blank from single-character options (e.g.
       -d epson) and by  a  "="  from  multi-character  options  (e.g.   --de-
       vice-name=epson).

       -d dev, --device-name=dev
              specifies  the  device  to access and must be followed by a SANE
              device-name like `epson:/dev/sg0' or  `hp:/dev/usbscanner0'.   A
              (partial)  list  of  available  devices can be obtained with the
              --list-devices option (see below).  If no device-name is  speci-
              fied explicitly, scanimage reads a device-name from the environ-
              ment variable SANE_DEFAULT_DEVICE.  If this variable is not set,
              scanimage will attempt to open the first available device.

       --format=format
              selects how image data is written to standard output or the file
              specified by the --output-file option.  format can be pnm, tiff,
              png,  or  jpeg.  If --format is not specified, PNM is written by
              default.

       -i profile, --icc-profile=profile
              is used to include an ICC profile into a TIFF file.

       -L, --list-devices
              requests a (partial) list of devices that  are  available.   The
              list  may  not  be complete since some devices may be available,
              but are not listed in any of the configuration files (which  are
              typically  stored  in  directory /etc/sane.d).  This is particu-
              larly the case when accessing scanners through the network.   If
              a  device is not listed in a configuration file, the only way to
              access it is by its full device name.  You may need  to  consult
              your system administrator to find out the names of such devices.

       -f format, --formatted-device-list=format
              works  similar  to --list-devices, but requires a format string.
              scanimage replaces the placeholders %d %v %m %t %i %n  with  the
              device  name,  vendor  name,  model name, scanner type, an index
              number and newline respectively. The command

              scanimage -f  scanner number %i device %d is a  %t,  model  %m,
              produced by %v 

              will produce something like:

                     scanner  number  0   device sharp:/dev/sg1 is  a  flatbed
                     scanner, model JX250 SCSI, produced by SHARP

       The --batch* options provide features for scanning documents using doc-
       ument feeders.

              -b [format], --batch=[format]
                     is  used  to specify the format of the filename that each
                     page will be written to.  Each page is written out  to  a
                     single  file.  If format is not specified, the default of
                     out%d.pnm (or out%d.tif for --format tiff, out%d.png  for
                     --format  png  or  out%d.jpg  for  --format jpeg) will be
                     used.  This option is incompatible with the --output-path
                     option.   format  is  given as a printf style string with
                     one integer parameter.

              --batch-start=start
                     selects the page number to start naming  files  with.  If
                     this option is not given, the counter will start at 1.

              --batch-count=count
                     specifies the number of pages to attempt to scan.  If not
                     given, scanimage will continue scanning until the scanner
                     returns  a  state  other  than OK.  Not all scanners with
                     document feeders signal when the ADF is empty.  Use  this
                     option to work around them.

              --batch-increment=increment
                     sets the amount that the number in the filename is incre-
                     mented by.  Generally this is used when you are  scanning
                     double-sided documents on a single-sided document feeder.
                     --batch-double is a  specific  command  provided  to  aid
                     this.

              --batch-double
                     will automatically set the increment to 2.  Equivalent to
                     --batch-increment=2

              --batch-prompt
                     will ask for pressing RETURN before scanning a page. This
                     can  be used for scanning multiple pages without an auto-
                     matic document feeder.

       --accept-md5-only
              only accepts user authorization requests that support MD5  secu-
              rity.  The SANE network daemon saned(8) is capable of doing such
              requests.

       -p, --progress
              requests that scanimage prints a progress counter. It shows  how
              much  image  data of the current image has already been received
              (in percent).

       -o path, --output-file=path
              requests that scanimage saves the scanning output to  the  given
              path.   This option is incompatible with the --batch option. The
              program will try to guess --format from the file name.  If  that
              is not possible, it will print an error message and exit.

       -n, --dont-scan
              requests  that  scanimage  only sets the options provided by the
              user but doesn't actually perform a scan.  This  option  can  be
              used  to  e.g.  turn off the scanner's lamp (if supported by the
              backend).

       -T, --test
              requests that scanimage performs a few simple  sanity  tests  to
              make  sure the backend works as defined by the SANE API. In par-
              ticular the sane_read() function is exercised by this test.

       -A, --all-options
              requests that scanimage lists all available options  exposed  by
              the  backend,  including  button  options.   The  information is
              printed on standard output and no scan will be performed.

       -h, --help
              requests help information.  The information is printed on  stan-
              dard output and no scan will be performed.

       -v, --verbose
              increases  the verbosity of the output of scanimage.  The option
              may be specified repeatedly, each time increasing the  verbosity
              level.

       -B [size], --buffer-size=[size]
              changes  input  buffer size from the default of 32KB to size KB.
              If size is not specified then the buffer is set to 1 MB.

       -V, --version
              requests that scanimage prints the program and package name, the
              version  number  of  the SANE distribution that it came with and
              the version of the backend that it loads.  If  more  information
              about the version numbers of the backends are necessary, the DE-
              BUG variable for the dll layer can be  used.  Example:  SANE_DE-
              BUG_DLL=3 scanimage -L .

       As  you  might  imagine,  much of the power of scanimage comes from the
       fact that it can control any SANE backend.  Thus, the exact set of com-
       mand-line  options  depends on the capabilities of the selected device.
       To see the options for a device named dev, invoke scanimage via a  com-
       mand-line of the form:

              scanimage --help --device-name dev

       The  documentation for the device-specific options printed by --help is
       best explained with a few examples:

       -l 0..218mm [0]
              Top-left x position of scan area.

              The description above shows that option  -l  expects  an  option
              value in the range from 0 to 218 mm.  The value in square brack-
              ets indicates that the current option value is 0 mm. Most  back-
              ends  provide  similar  geometry options for top-left y position
              (-t), width (-x) and height of scan-area (-y).

       --brightness -100..100% [0]
              Controls the brightness of the acquired image.

              The description above shows that option --brightness expects  an
              option  value  in the range from -100 to 100 percent.  The value
              in square brackets indicates that the current option value is  0
              percent.

       --default-enhancements
              Set default values for enhancement controls.

              The  description  above shows that option --default-enhancements
              has no option value.  It should be thought of as having an imme-
              diate  effect  at  the point of the command-line at which it ap-
              pears.  For example, since this option resets  the  --brightness
              option,  the  option-pair --brightness 50 --default-enhancements
              would effectively be a no-op.

       --mode Lineart|Gray|Color [Gray]
              Selects the scan mode (e.g., lineart or color).

              The description above shows that option --mode accepts an  argu-
              ment  that  must  be one of the strings Lineart, Gray, or Color.
              The value in the square bracket indicates  that  the  option  is
              currently set to Gray.  For convenience, it is legal to abbrevi-
              ate the string values as long as they remain unique.  Also,  the
              case  of  the spelling doesn't matter.  For example, option set-
              ting --mode col is identical to --mode Color.

       --custom-gamma[=(yes|no)] [inactive]
              Determines whether a builtin or a custom gamma-table  should  be
              used.

              The  description  above shows that option --custom-gamma expects
              either no option value, a "yes" string, or a "no" string.  Spec-
              ifying  the  option  with  no  value is equivalent to specifying
              "yes".  The value in square-brackets indicates that  the  option
              is  not currently active.  That is, attempting to set the option
              would result in an error message.  The set of available  options
              typically  depends  on the settings of other options.  For exam-
              ple, the --custom-gamma  table  might  be  active  only  when  a
              grayscale or color scan-mode has been requested.

              Note  that  the  --help option is processed only after all other
              options have been processed.  This makes it possible to see  the
              option  settings  for a particular mode by specifying the appro-
              priate mode-options along with the --help option.  For  example,
              the command-line:

              scanimage --help --mode color

              would  print  the  option  settings  that are in effect when the
              color-mode is selected.

       --gamma-table 0..255,...
              Gamma-correction table.  In color mode this option  equally  af-
              fects the red, green, and blue channels simultaneously (i.e., it
              is an intensity gamma table).

              The description above shows that  option  --gamma-table  expects
              zero or more values in the range 0 to 255.  For example, a legal
              value for this option would be "3,4,5,6,7,8,9,10,11,12".   Since
              it's  cumbersome  to specify long vectors in this form, the same
              can be expressed by the  abbreviated  form  "[0]3-[9]12".   What
              this  means  is  that  the first vector element is set to 3, the
              9-th element is set to 12 and the values in between are interpo-
              lated  linearly.   Of course, it is possible to specify multiple
              such linear segments.  For example,  "[0]3-[2]3-[6]7,[7]10-[9]6"
              is    equivalent   to   "3,3,3,4,5,6,7,10,8,6".    The   program
              gamma4scanimage can be used to generate such gamma  tables  (see
              gamma4scanimage(1) for details).

       --filename <string> [/tmp/input.ppm]
              The filename of the image to be loaded.

              The  description  above is an example of an option that takes an
              arbitrary string value (which happens to be a filename).  Again,
              the value in brackets show that the option is current set to the
              filename /tmp/input.ppm.

ENVIRONMENT
       SANE_DEFAULT_DEVICE
              The default device-name.

FILES
       /etc/sane.d
              This directory holds various configuration files.  For  details,
              please refer to the manual pages listed below.

       ~/.sane/pass
              This file contains lines of the form

              user:password:resource

              scanimage uses this information to answer user authorization re-
              quests automatically. The file must  have  0600  permissions  or
              stricter. You should use this file in conjunction with the --ac-
              cept-md5-only option to avoid server-side attacks. The  resource
              may contain any character but is limited to 127 characters.

SEE ALSO
       sane(7),    gamma4scanimage(1),   xscanimage(1),   xcam(1),   xsane(1),
       scanadf(1), sane-dll(5), sane-net(5), sane-"backendname"(5)

AUTHOR
       David Mosberger, Andreas Beck, Gordon Matzigkeit, Caskey  Dickson,  and
       many  others.   For questions and comments contact the sane-devel mail-
       inglist (see http://www.sane-project.org/mailing-lists.html).

BUGS
       For vector options, the help output currently has no indication  as  to
       how many elements a vector-value should have.

                                  10 Jul 2008                     scanimage(1)

Generated by dwww version 1.15 on Tue Jun 18 17:05:59 CEST 2024.