dwww Home | Show directory contents | Find package

************************  Release of sane-backends 1.0.4 **********************

2000-12-22  Henning Meier-Geinitz <hmg@gmx.de>

        * configure configure.in: Changed version to 1.0.4 and package to
          sane-backends (from Oliver Rauch <Oliver.Rauch@Wolfsburg.DE).
        * sane.lsm Removed (renamed to sane-backends.lsm).
        * sane-backends.lsm New file. Package name is sane-backends instead
          of sane and added additional maintainer: Oliver Rauch (from
          Oliver Rauch <Oliver.Rauch@Wolfsburg.DE).

2000-12-17  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Some points about OS/2 compilation problems.

2000-12-17  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: More details for net/saned problems.

2000-12-16  Jochen Eisinger <jochen.eisinger@gmx.net>

        * TODO: removed entry about net.c seg-faulting when saned isn't
          loaded or timed-out

2000-12-16  Henning Meier-Geinitz <hmg@gmx.de>

        * configure configure.in: Disable warnings by default for release.
        * sanei/sanei_wire.c: Fixed typo.

2000-12-16  Jochen Eisinger <jochen.eisinger@gmx.net>

        * sanei/sanei_wire.c: added test for negative parameter to memcpy()

2000-12-15 Gerhard Jaeger <g.jaeger@earthling.net>

        * fixed wrong options in sane-plustek.man

2000-12-12 Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * corrected backend version in umax.desc

**************************  Code freeze for SANE 1.0.4 ** *********************

2000-12-12  Henning Meier-Geinitz <hmg@gmx.de>

        * NEWS: Updated/corrected version numbers of backends.

2000-12-10  Henning Meier-Geinitz <hmg@gmx.de>

        * doc/sane-scsi.man: Small changes/updates concerning Linux
          2.2. Updated entries about Adaptec cards, NCR53c400/Domex 3181
          cards, NCR 810 cards. Removed direct links to some backends.
        * doc/sane-snapscan.man: Added link to new snapscan website.

2000-12-10  Henning Meier-Geinitz <hmg@gmx.de>

        * backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
          Fixed wrong comment in encode_resolution. Added missing test for
          return status in sane_start.  Fixed wrong calculation of tlx and
          tly for Pro series scanners. Increased version number.

2000-12-09  Karl Heinz Kremer <khk@khk.net>

        * backend/epson.c: Fixed user defined gamma curve for
          inverted images. When scanning negatives the gamma curve
          was applied incorrectly. Fixed debug output for user defined
          gamma curves - no [epson] in between values anymore.

2000-12-09  Peter Kirchgessner <peter@kirchgessner.net>

        * doc/sane-hp.man, backend/hp.desc
          Add HP ScanJet 6390C to list of supported scanners

2000-12-07  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Updated. Removed entries about plustek comment problembelm
          and libsane.la. Added entry about disabling local scanning.

2000-12-07 Gerhard Jaeger <g.jaeger@earthling.net>

    * backend/plustek-share.h backend/plustek.h backend/plustek.c
      removed warning conditions
      fixed a bug that causes wrong frontend displays
      fixed problem when driver returns error during read

2000-12-05  Henning Meier-Geinitz <hmg@gmx.de>

        * NEWS: Updated backend versions. Added point about compilation fixes
          on Irix and FreeBSD.
        * backend/mustek.c backend/mustek.desc backend/mustek.CHANGES:
          Fixed problem with lamp control of SE scanners and reduced
          length of scan area for Paragon 1200 SP PRO. Removed warning for
          this scanner. Increased version number.

2000-12-05  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Updated. Added point about plustek-share.h using c++ comment
          and reminder to check config.in.h. Removed entriy about as6e.c stat
          result check.
        * backend/as6e.c backend/as63.h: Committed patch from Eugene Weiss
          <eweiss@sas.upenn.edu>. Fixes: Use only DBG (no printfs). Check result
          of stat. Add GPL header.

2000-12-05 Gerhard Jaeger <g.jaeger@earthling.net>

        * backend/plustek-share.h
          cleanup

2000-12-05  Peter Kirchgessner <peter@kirchgessner.net>

        * backend/hp-handle.c
          - Change SCL_UNLOAD to SCL_CHANGE_DOC (bug from copying code)

2000-12-04  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Updated. Added entries about as6e stat problems and addition to
          sanei_scsi.c from FreeBSD ports.

*************************  snapshot-2000-12-04  *******************************

2000-12-04  Peter Kirchgessner <peter@kirchgessner.net>

        * backend/hp.c, hp-handle.c, hp.desc
          - fix problem with ADF support on 6350C (and maybe others)

2000-12-04  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * removed usage of gettext, problem with -lintl should be solved:
          - removed usage of gettext from lib/getopt.c
          - removed test for libintl/gettext in configure[.in]
          - removed intllib from frontend/Makfile.in
        * updated umax.desc

2000-12-03  Karl Heinz Kremer <khk@khk.net>

        * backend/epson.*: Version 0.1.38
          Removed changes regarding 12/14 bit support because of SANE
          feature freeze for 1.0.4.
          The following fixes are in the software compared to the version
          prior to the feature freeze:
          - refresh UI after a change in the scan mode setting (was not updated
            when going from Binary to Gray or vice versa)
          - Read values for "line distance" from the scanner instead of using
            hardcoded values. This makes sure the backend always uses the correct
            values regardless of firmware version.
          - Fixed an "off-by-one" error in the color reordering routine that
            caused weird artifacts in some instances.

2000-12-03  Karl Heinz Kremer <khk@khk.net>

        * backend/epson.c: Fixed off-by-one in color reordering

2000-12-02  Karl Heinz Kremer <khk@khk.net>

        * backend/epson.*: Read information about optical resolution
          and line distance from scanner instead of hardcoded values.
          Add support for color depth > 8 bits per channel.
          (can use 12, 14 and 16 bits per channel)
          EPSON backend is now version 0.36

2000-11-30  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * changed backend/Makefile.in:
          wrong old installation of libsane.la
          $(INSTALL_PROGRAM) libsane.la $(libdir)/libsane.la
          to this:
          $(LIBTOOL) $(MINST) $(INSTALL_PROGRAM) libsane.la $(libdir)/libsane.la

2000-11-30  Henning Meier-Geinitz <hmg@gmx.de>

        * README.irix: Removed. Problem with libjpeg is solved.
        * TODO: Updated. Removed hpoj addition. Added snapscan link. Added
          entry about net backend segfaulting if using net:localhost. Removed
          artec O_SYNC problem. Removed Irix jpeg problem. Removed PTAL
          addition.
        * doc/saned.man: Added paragraph about xinetd (from Matt Mozur
          <matt.mozur@sourwood.net>). Removed links to backends, added
          sane-"backendname" instead.
        * doc/sane-net.man: Added comment about segfaults if scanning
          on localhost.
        * sanei/sanei_scsi.c: Added missing DBG_INIT (from FreeBSD ports).

2000-11-30 Gerhard Jaeger <g.jaeger@earthling.net>

        * backend/plustek.c backend/plustek.desc backend/plustek-share.h
          backend/plustek.h doc/sane-plustek.man:
          changed to version 0.38 - document update, minor bugfixes

2000-11-30  Chris Pinkham <cpinkham@infi.net>

        * artec.c: removed O_SYNC for posix compatibility, converted variable
          to unsigned char to get rid of overflow error.  Changed version
          to 0.5.15.

2000-11-30  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * changed sane-config.in again:
          sane-config --libs has to print all libs
          that the sane libs depend on.
          This is not needed for shared libs and that
          was the reason why I removed all libs but "-lsane".
          But when linking against static sane libs we need
          to know about all necessary libs.

*************************  snapshot-2000-11-28  *******************************

2000-11-28  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * added SANE_CHECK_JPEG to aclocal.m4 and configure.in
          (test routine by henning Meier Geinitz)

*************************  Feature freeze for SANE 1.0.4  *********************

2000-11-27  Peter Kirchgessner <peter@kirchgessner.net>

        * NEWS: hp-backend version is 0.92

2000-11-27  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * backend/umax.c: corrected wrong BUILD (25->24)

2000-11-26  Henning Meier-Geinitz <hmg@gmx.de>

        * AUTHORS: Added Karsten Festag as maintainer of microtek2.
        * backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
          1.0-100. Added option fast-preview that tries to use the fastest
          mode available for preview. This is supported for the 3-pass
          scanners (was option "preview in gray") and some of the
          ScanExpress scanners (6000 SP, 12000 SP Plus). Use #include
          "../include/sane/...". Put option force-wait into mustek.conf
          (disabled). Removed block mode for Paragon 6000 SP and 8000 SP.
          Code cleanup. More debug output. Details in backend/mustek.CHANGES.
        * doc/.cvsignore: Added sane-as6e.5 and sane-nec.5.

2000-11-26  Peter Kirchgessner <peter@kirchgessner.net>

        * backend/hp.desc, doc/sane-hp.man
          Add descriptions for PTAL support

        * backend/hp.c
          If PTAL-support requested, write warning about unsupported PTAL
          with DBG(0,...  instead of DBG(1,...

2000-11-25  Henning Meier-Geinitz <hmg@gmx.de>

        * configure configure.in acinclude.m4 aclocal.m4
          include/sane/config.h.in: Added test for PTAL library and headers
          (patch from David Paschal <paschal@rcsis.com>). Some reformatting of
          the output of configure --help.

        * backend/GUIDE: Updated entry about #include.

2000-11-24  Henning Meier-Geinitz <hmg@gmx.de>

        * AUTHORS: Removed authors of xscanimage and xcam (now in
          sane-frontends).
        * README.unixware2, README.unixware7: X-frontends are no longer
          included. Removed comments and sourcecode of "rev" (not supported/used
          in backends/Makefile anymore).
        * sane.lsm: X-frontends are no longer included. Used blanks instead of
          tabs.
        * doc/scanimage.man: Removed links to backends, added generic link
          instead.
        * doc/.cvsignore frontend/.cvsignore: X-frontends are no longer included.

2000-11-24  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * changed configure.in, configure frontend/Makefile.in
          and backend/Makfile.in:
          The shared libraries required by the backends are linked to
          the backends (they have been linked to the frontends before).
          Only libintl is linked to the frontend.
        * changed tool/sane-config.in, sane-config --libs => "-lsane",
          all other libraries are linked to the backend libs now

2000-11-24  Jochen Eisinger <jochen.eisinger@gmx.net>

        * doc/scanimage.man doc/saned.man: updated description of password
          file
        * sanei/sanei_auth.c frontend/saned.c frontend/scanimage.c: replaced
          index() by strchr(). Changed style of password file
        * backend/net.c: the net backend now prepends net:host: to the
          resource before calling the auth_callback function

2000-11-23  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * removed doc/xcam.man, doc/xscanimage.man and
          updated doc/Makefile.in
        * changed configure.in and frontend/Makefile.in,
          "-lintl" is not added to @LIBS@ any more, @INTLLIBS@
          is defined instead now, this is necessary because "-lintl"
          has to be added to the frontends and not to a backend and
          sane-config --libs must not list it.
        * Added "Introduction" to README that tells about
          the new X-frontend package
        * removed gimp and gtk parts from include/sane/config.h.in
        * removed gtk test from aclocal.m4
        * removed xcam.c xscanimage.c sane-style.rc progress.c progress.h
                  preview.c preview.h preferences.c preferences.h gtkglue.c gtkglue.h
          from frontend/
        * removed parts for xcam and xscanimage from frontend/Makefile.in,
          configure.in and updated confiugre

2000-11-23  Henning Meier-Geinitz <hmg@gmx.de>

        * NEWS: Updated for SANE 1.0.4. Please check.
        * README.aix: Removed paragraph about shared libs not working.
        * README.linux: Added paragraph about excessive warnings due to glibc
          bug (from Peter Kirchgessner).
        * TODO: Removed entry about shared libs not working on AIX. Added entry
          about PTAL checks. Removed entry about DBG and microtek2. Added entry
          about dc210 and jpeg functions. Added entry about using strchr()
          instead of index().
        * sane.lsm: Added NEC.
        * backend/microtek2.c: (from karsten.festag@t-online.de (Karsten
          Festag)) Use DBG instead of printf/fprintf. Use
          #include "../sane/include/..." instead of #include "sane/...". Fixed
          warnings.

2000-11-23  Karl Heinz Kremer <khk@khk.net>

        * backend/epson.c:  Display "Set Focus" control only for scanners that
          can actually handle the command.

2000-11-22  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * changed configure and configure.in, removed test for string.h/strings.h
          this is not needed because we use strchr instead (always in string.h)
          of index (sometimes in string.h, sometimes in strings.h)

        * changed ltconfig for aix4*, repleace -o $objdir/$soname by -o $lib,
          the shared libraries are handled correct now

2000-11-21 Abel Deuring <a.deuring@satzbau-gmbh.de>
        * backend/sharp.c, backend/sharp.desc, doc/sharp.man: Support
          for JX320 added

2000-11-21  Henning Meier-Geinitz <hmg@gmx.de>

        * AUTHORS: Added FUKUDA Kazuya for the nec Backend. Used spaces instead
          of tabs.
        * PROJECTS: Removed entry about NEC. Added/updated entries about Mustek
          USB scanners.
        * README: Added link to sane-nec(5).
        * TODO: Removed entries about sanei_authorize and plain text passwords.
        * backend/Makefile.in backend/dll.conf backend/nec.conf backend/nec.c
          backend/nec.desc backend/nec.h doc/Makefile.in doc/sane-nec.man:
          Added nec backend for the NEC scanners PC-IN500/4C (from Kazuya Fukuda
          <fukuda@pjs.nevt.nec.co.jp>)

2000-11-20  Henning Meier-Geinitz <hmg@gmx.de>

        * AUTHORS: Added Eugene S. Weiss.
        * PROJECTS: Removed Artec as6e backend.
        * README: Added link to man sane-as6e.5.
        * TODO: Removed as6e.
        * doc/Makefile.in: Added generation of as6e manpage.
        * backend/Makefile.in: Added entries for as6e.
        * backend/dll.conf: Added as6e.
        * backend/as6e.c backend/as6e.h backend/as6e.desc doc/sane-as6e.man:
          Added backend for Artec AS6E parallel port scanner (from Eugene S.
          Weiss <yossarian@users.sourceforge.net>).

2000-11-20  Jochen Eisinger <jochen.eisinger@gmx.net>

        * configure configure.in: Added test for /dev/urandom and
          index() in string.h or strings.h
        * backend/net.c: Fixed SANE_NET_AUTHORIZE call handling
        * doc/net.tex: Clarified definition of SANE_NET_AUTHORIZE, added
          definition of MD5 authorization
        * doc/sane.tex: Upgraded to version 1.0.2, changed definition of
          SANE_MAX_USERNAME_LEN & SANE_MAX_PASSWORD_LEN to 128 chars
        * doc/saned.man: added description of SANE_CONFIG_DIR/saned.users
        * doc/scanimage.man: added description of ~/.sane/pass and
          --accept-md5-only
        * frontend/saned.c: implemented user authorization on a per backend
          basis
        * frontend/scanimage.c: fixed bug (option -b wasn't present)
          implemented auth_callback
        * lib/md5.c include/md5.h: added md5 functions from GNU textutils
        * include/sane/sane.h: changed definition of SANE_MAX_USERNAME_LEN &
          SANE_MAX_PASSWORD_LEN to 128 chars
        * include/sane/sanei_auth.h sanei/sanei_auth.c: implemented new
          SANE interface for user authorization using MD5 digest
        * lib/Makefile.in sanei/Makefile.in: updated Makefiles

2000-11-19  Karl Heinz Kremer <khk@khk.net>

        * backend/epson.c: Removed one debug output statement.

2000-11-19  Karl Heinz Kremer <khk@khk.net>

        * backend/epson.[ch]: Added support for "set focus position" command. This
          command is necessary to scan via the TPU with the Expression1600.
2000-11-19  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Removed entry about stiff.*. Updated entry about testing
          saned.

2000-11-19  Jochen Eisinger <jochen.eisinger@gmx.net>

        * backend/mustek_pp.[ch]: replaced #include "sane/.." by
          #include "../include/sane/.."

2000-11-19  Peter Kirchgessner <peter@kirchgessner.net>

        * frontend/stiff.c: Fix problem with writing Tag bits per sample
          for color tiff files.

2000-11-18  Jochen Eisinger <jochen.eisinger@gmx.net>

        * doc/sane-mustek_pp.man backend/mustek_pp.*: updated mustek_pp
          backend to version 0.9-devel

2000-11-15  Henning Meier-Geinitz <hmg@gmx.de>

        * PROJECTS: Added entry about Visioneer OneTouch 8600.
        * TODO: Added entries about net backend crashing after timeout, stiff.c
          problems, and more details about Irix cc jpeg problems.

2000-11-15  Rene Rebe <rene.rebe@gmx.net>
        * backend/avision.[c,h]: some fixes for brightness and contrast via
          the gamma-table. New config-option to force the backend to use DIN A4
          ("option force-a4"). Clean up.

2000-11-14  Rene Rebe <rene.rebe@gmx.net>
        * backend/avision.[h,c]: Added gamma table support in hardware.
          Brightness and contrast emulation via the hardware gamma table.
          Code cleanup.
        * AUTHORS: Changed my e-mail address.

2000-11-13  Henning Meier-Geinitz <hmg@gmx.de>

        * Makefile.in: Install sane.h and saneopts.h only.
        * PROJECTS: Removed sane-pie.
        * TODO: Removed sane-pie. Added possible portability problem for
          artec. Removed entry about installed headers. Added entry about
          gettext and libdl.
        * doc/.cvsignore: Added sane-pie.5.

2000-11-13  Simon Munton <simon@munton.demon.co.uk>

        * backend/pie.c backend/pie-scsidef.c backend/pie.conf backend/pie.desc
          doc/sane-pie.man: Added Pacific Image Electronics backend for ScanAce
          range of scanners (also supports DevCom BlackWidow scanners and ADLIB
          JetScan scanners).
        * README backend/Makefile.in backend/dll.conf doc/Makefile.in: Added pie
          backend.
        * sane.lsm: Added keywords for pie backend.
        * AUTHORS: Added myself as maintainer of pie backend.

2000-11-12  Henning Meier-Geinitz <hmg@gmx.de>

        * doc/sane.tex: Fixed a typo.
        * doc/.cvsignore: Added the files produced by make ps.
        * README: Removed X-frontends. Point to sane-frontends and website.
          Some reformatting.
        * TODO: Updated concerning frontends split.
        * PROJECTS: Removed entries about frontends (now in
          sane-frontends/README)
        * PROBLEMS: Removed entries about frontends (now in
          sane-frontends/PROBLEMS)

2000-11-10  Henning Meier-Geinitz <hmg@gmx.de>

        * sanei/sanei_constrain_value.c: If constraint_type is
          SANE_CONSTRAINT_RANGE and quantization is used, the results may
          be outside the limits of the range because quantization uses the
          original value. Fixed by doing quantization with the already
          checked value.

2000-11-10 Gerhard Jaeger <g.jaeger@earthling.net>

        * backend/plustek.c backend/plustek.desc backend/plustek-share.h
      backend/plustek.h doc/sane-plustek.man:
          updated to version 0.37 - support for xsane, new models
      document update, minor bugfixes

2000-11-08  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Updated. Added entries for viceo backend and addition to hp
          backend. Updated entries about the include issue. Added point about
          additional options for pnm backend, install problem of libsane.la,
          and some build problems and the --without-x problem. Some more
          details for detecting older SANE versions.

        * LEVEL2: Added entry about sending messages from backend to frontend.
          Removed entry about image polarity.

        * backend/mustek.c backend/mustek.h backend/mustek.CHANGES
      backend/mustek.desc: Update to Mustek backend 1.0-99. Better
          transparency adapter support for ScanExpress scanners. Changed
          color support for ScanExpress scanners (faster at some resolutions
          now). Paragon 1200 SP color mode should work now without garbage at
          the end of an image. Some bugfixes. Details in
          backend/mustek.CHANGES.

2000-11-08  Jochen Eisinger <jochen.eisinger@gmx.net>

        * include/sane/sanei_debug.h: fixed typo

2000-10-30  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Updated. Added points about --without-x and the
          #include <sane...> stuff. Added xcam problem. Changed entry for
          Relisys scanner.

2000-10-30  Petter Reinholdtsen <pere@td.org.uit.no>

        * frontend/xscanimage.c: Define GIMP_ENABLE_COMPAT_CRUFT when
        including gimp.h to use the old API.  Eventually we should convert
        the frontends to use the new Gimp API.  Patch from Kevin Dalley.

2000-10-29  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Updated.

2000-10-23  Peter Kirchgessner <peter@kirchgessner.net>

        *backend/hp-accessor.c hp-device.c hp-handle.c hp-hpmem.c hp.h hp.c
                 hp-option.c  hp-scl.c: Change sanei_debug-interface
            Allocate accessors once (for fixed size accessors)
            Close connection in some error conditions

2000-10-23  Jochen Eisinger <jochen.eisinger@gmx.net>

        * backend/dll.c: added test for ``dll'' in dll.conf

2000-10-23  Jochen Eisinger <jochen.eisinger@gmx.net>

        * sanei/sanei_init_debug.c include/sane/sanei_debug.h
          frontend/saned.c: removed vararg macros

2000-10-17  Henning Meier-Geinitz <hmg@gmx.de>

        * doc/sane.tex: Added paragraph about image polarity as discussed
          on sane-devel. This is the version from Nick Lamb.

2000-10-15  Jochen Eisinger <jochen.eisinger@gmx.net>

        * include/sane/sanei_debug.h: sanei_debug_init was only declared
          if VARARG macros are supported. Fixed this.

2000-10-08  Jochen Eisinger <jochen.eisinger@gmx.net>

        * sanei/sanei_pa4s2.c: fixed all but one compiler warning

2000-10-03  Henning Meier-Geinitz <hmg@gmx.de>

        * tools/find-scanner.c: Explicitly state that find-scanner won't
          find non-SCSI scanners.
        * doc/scanimage.man: Add examples for SANE device names.
        * frontend/scanimage.c: Output message when no devices are found.
          Add example for devicename to --help message. Print warning
          when a Unix devicename is used instead of a SANE device. Removed
          compiler warning.
        * TODO: Removed entries about the fgets and include issues in
          umax. Removed entries about scanimage device name
          documentation. Added a point about xscanimage problems with the
          new GIMP API.
        * backend/mustek.* doc/sane-mustek.man: Update to Mustek backend
          1.0-98. Fixed segmentation fault in sane_init. Enabled double
          buffering. Clear inquiry buffer before using. Paragon 1200 SP now
          uses LD_BLOCK color correction. Removed LD MFS (wasn't used
          anymore). Fix sane_cancel for Paragon series II scanners. Fix
          halftone and grain for Paragon series II scanners. Backtracking is
          used automatically by all scanners now. Some safety checks, code
          cleanup and more debug output. Details are in
          backend/mustek.CHANGES.

2000-10-02  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * Updated umax backend to sane-umax-1.0.3-build-24
          take a look at backend/umax.CHANGES for details

2000-10-02  Oliver Rauch <Oliver.Rauch@Wolfsburg.DE>

        * sanei/sanei_constrain_value.c:
          if checked option is a range and the value is out of
          range the value is now corrected to the minimum or maximum
          allowed value and SANE_INFO_INEXACT is set.
          The old version returned with an error. This caused problems
          when the value was a little bit out of range because of rounding
          errors.

2000-09-30  Henning Meier-Geinitz <hmg@gmx.de>

        * backend/pnm.c: Fixed three segfaults due to buffer overruns:
          maximum length of filename wasn't checked; maximum length in
          sane_read wasn't always checked; ppm_type wasn't always set in
          getparmfromfile. Added some checks for safety and removal of
          warnings. Added DBG lines for every SANE API call.
        * TODO: Added entries about the backend:devicename issue. Add a
          comment about fronends not to crash when length is -1. Added entry
          about sane-pie. Added point about fronends not checking if too
          much data is delivered with sane_read.
        * PROJECTS: Added entry about sane-pie.

2000-09-24  Henning Meier-Geinitz <hmg@gmx.de>

        * backend/mustek.*: Update to Mustek backend 1.0-97. This is a
          development version and is only tested for three-pass scanners.
          Added support for Paragon 1200 SP Pro and ScanExpress A3 SP.
          Removed detection of " C04" and " C12" (don't seem to exist).
          Changed SCSI request scheme. Sane_read can read more than 4096
          bytes from pipe. Minimum dpi is 30 now. Fixed LD correction for
          Paragon 1200SP 1.06 and 1.11.  Read SCSI buffer into big block and
          do LD after that for Paragon one-pass scanners. New option
          "blocksize" in mustek.conf. Better detection of the scanner type
          (three-pass, Paragon I, ...). Fixed possible segmentation faults
          in Paragon 600 II N LD code, scsi_sense_wait_ready and
          sense_handler. Decreased maximum scan size of Paragon 800 II
          SP. For three-pass scanners: fixed stop_scan and speed code, scan
          area is in pixels now, added RGB brightness and contrast, use
          +-100% for brightness and contrast. Return SANE_STATUS_CANCELLED
          when scan was cancelled. Option "force backtracking" is enabled by
          default, "scan speed" is set to "fastest". Added option
          "force-warn" for mustek.conf.  Rewrote halftone mode. Better error
          handling and more debug output.
        * TODO: Clarified point about image data polarity. Moved point about
          xscanimage not updating the progress bar for 3pass scanners to
          frontend section. Removed umax entry in "frontends". Removed entry
          about alpha channel (was added to LEVEL2 file).
        * LEVEL2: Add point about image data polarity.
        * frontend/scanimage.c: Removed some warnings.

2000-09-19  Gerhard Jaeger <g.jaeger@earthling.net>

        * backend/plustek.desc doc/sane-plustek.man:
          updated information about supported scanners

2000-09-18  Henning Meier-Geinitz <hmg@gmx.de>

        * README: Removed comment about xscanimage error message. Added
          comment about find-scanner (may find scanners not supported by
          SANE).
        * tools/README: Added comment about find-scanner and some lines
          about sane-desc.el and sane-config.
        * tools/find-scanner.c: Added comment about scanners not supported
          by SANE. Removed some warnings.
        * TODO LEVEL2: Removed xscanimage error comment from TODO and moved
          ideas for SANE 2.0 from TODO to LEVEL2.

2000-09-18  Petter Reinholdtsen <pere@td.org.uit.no>

        * backend/v4l.c: Remove X11 dependency.

2000-09-17  Henning Meier-Geinitz <hmg@gmx.de>

        * frontend/xscanimage.c: Fixed gtk_main_quit bug (based on patch
          from <moloch@nikocity.de>). An error message was printed when
          no sane device was found.

2000-09-17  Petter Reinholdtsen <pere@td.org.uit.no>

        * config.guess config.sub : Upgraded to latest version from
        <URL:ftp://ftp.gnu.org/pub/gnu/config/>.

        * doc/Makefile.in: New target 'install-docs' to install
        documentation in $(prefix)/doc/sane-<version>/.

        * japi/Makefile.in: Move javac and javah to make variables.

2000-09-16  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Added xscanimage bug and information about versioning
          problems. Some other minor changes.

2000-09-15 Gerhard Jaeger <g.jaeger@earthling.net>

        * backend/plustek.c
          added some code to support timing measurement in debug sessions

2000-09-10 Peter Kirchgessner <peter@kirchgessner.net>

        * backend/hp-handle.c
            Special handling of sane_cancel for OfficeJet K series

2000-09-09 Peter Kirchgessner <peter@kirchgessner.net>

        * backend/hp.h hp-scsi.h hp-scl.h hp-option.h hp-option.c
                  hp-device.h hp-scl.c hp.c hp-device.c hp-handle.c

          David Paschal (paschal@rcsis.com)
            Added support for flatbed HP OfficeJets.
          fix problem with cancel preview
          fix timing problem between killing child and writing to pipe
          change fprintf(stderr,...) to DBG
          change include <sane..> to "sane.." in hp.h
          change handling of options that have global effects.
            i.e. if option scanmode is received (has global effect),
            all options that "may change" are send to the scanner again.
            This fixes a problem that --resolution specified infront of
            --mode on command line of scanimage was ignored.
            NOTE: This change does not allow to specify --depth 12 infront of
            --mode color, because --depth is only enabled with --mode color.
          add depth greater 8 bits for mode grayscale
          add option for 8 bit output but 10/12 bit scanning

2000-08-24 Gerhard Jaeger <g.jaeger@earthling.net>

        * Updated plustek backend to support multiple devices and 12bit color-depth
          affected files: backend/plustek.c backend/plustek.h
                          backend/plustek-share.h backend/plustek.conf
        * backend/plustek.desc: updated information about supported scanner
        * doc/sane-plustek.man: updated manpage according to the changes

2000-08-23 Abel Deuring <a.deuring@satzbau-gmbh.de>
        * sanei/sanei_scsi.c: Second attempt to fix the errno bug
          in the Linux command queue handling.

2000-08-19  Henning Meier-Geinitz <hmg@gmx.de>

        * TODO: Included TODO file for 1.0.4.
        * sanei/sanei_ab306.c: Removed some comiler warnings.
        * doc/sane.tex: Set \date to the date of the last change (not
          the date of running latex (\today))
        * frontend/xscanimage.c: Fixed image size overrun (>ca. 400 MB).
          Removed some compiler warnings.

2000-08-15  Henning Meier-Geinitz <hmg@gmx.de>

        * configure configure.in: Default to --enable-warnings again.

2000-08-15  Jochen Eisinger <jochen.eisinger@gmx.net>

        * backend/mustek_pp.c: fixed bug in config_ccd_1013 that prevents
        ASIC 1013 scanners from working

Generated by dwww version 1.15 on Sun Jun 23 21:16:33 CEST 2024.