dwww Home | Show directory contents | Find package

BlueZ D-Bus Profile API description
***********************************


Profile Manager hierarchy
=========================

Service         org.bluez
Interface       org.bluez.ProfileManager1
Object path     /org/bluez

                void RegisterProfile(object profile, string uuid, dict options)

                        This registers a profile implementation.

                        If an application disconnects from the bus all
                        its registered profiles will be removed.

                        Some predefined services:

                        HFP AG UUID: 0000111f-0000-1000-8000-00805f9b34fb

                                Default profile Version is 1.7, profile Features
                                is 0b001001 and RFCOMM channel is 13.
                                Authentication is required.

                        HFP HS UUID: 0000111e-0000-1000-8000-00805f9b34fb

                                Default profile Version is 1.7, profile Features
                                is 0b000000 and RFCOMM channel is 7.
                                Authentication is required.

                        HSP AG UUID: 00001112-0000-1000-8000-00805f9b34fb

                                Default profile Version is 1.2, RFCOMM channel
                                is 12 and Authentication is required. Does not
                                support any Features, option is ignored.

                        HSP HS UUID: 00001108-0000-1000-8000-00805f9b34fb

                                Default profile Version is 1.2, profile Features
                                is 0b0 and RFCOMM channel is 6. Authentication
                                is required. Features is one bit value, specify
                                capability of Remote Audio Volume Control
                                (by default turned off).

                        Available options:

                                string Name

                                        Human readable name for the profile

                                string Service

                                        The primary service class UUID
                                        (if different from the actual
                                         profile UUID)

                                string Role

                                        For asymmetric profiles that do not
                                        have UUIDs available to uniquely
                                        identify each side this
                                        parameter allows specifying the
                                        precise local role.

                                        Possible values: "client", "server"

                                uint16 Channel

                                        RFCOMM channel number that is used
                                        for client and server UUIDs.

                                        If applicable it will be used in the
                                        SDP record as well.

                                uint16 PSM

                                        PSM number that is used for client
                                        and server UUIDs.

                                        If applicable it will be used in the
                                        SDP record as well.

                                boolean RequireAuthentication

                                        Pairing is required before connections
                                        will be established. No devices will
                                        be connected if not paired.

                                boolean RequireAuthorization

                                        Request authorization before any
                                        connection will be established.

                                boolean AutoConnect

                                        In case of a client UUID this will
                                        force connection of the RFCOMM or
                                        L2CAP channels when a remote device
                                        is connected.

                                string ServiceRecord

                                        Provide a manual SDP record.

                                uint16 Version

                                        Profile version (for SDP record)

                                uint16 Features

                                        Profile features (for SDP record)

                        Possible errors: org.bluez.Error.InvalidArguments
                                         org.bluez.Error.AlreadyExists

                void UnregisterProfile(object profile)

                        This unregisters the profile that has been previously
                        registered. The object path parameter must match the
                        same value that has been used on registration.

                        Possible errors: org.bluez.Error.DoesNotExist


Profile hierarchy
=================

Service         unique name
Interface       org.bluez.Profile1
Object path     freely definable

Methods         void Release() [noreply]

                        This method gets called when the service daemon
                        unregisters the profile. A profile can use it to do
                        cleanup tasks. There is no need to unregister the
                        profile, because when this method gets called it has
                        already been unregistered.

                void NewConnection(object device, fd, dict fd_properties)

                        This method gets called when a new service level
                        connection has been made and authorized.

                        Common fd_properties:

                        uint16 Version          Profile version (optional)
                        uint16 Features         Profile features (optional)

                        Possible errors: org.bluez.Error.Rejected
                                         org.bluez.Error.Canceled

                void RequestDisconnection(object device)

                        This method gets called when a profile gets
                        disconnected.

                        The file descriptor is no longer owned by the service
                        daemon and the profile implementation needs to take
                        care of cleaning up all connections.

                        If multiple file descriptors are indicated via
                        NewConnection, it is expected that all of them
                        are disconnected before returning from this
                        method call.

                        Possible errors: org.bluez.Error.Rejected
                                         org.bluez.Error.Canceled