#!F-adobe-helvetica-medium-r-normal--18* #!N #!N #!Rdxlinpn DXLInputNamed #!N #!N Category #!N #!N #!Lcatdxl,dxall753 h DXLink #!EL #!N #!N Function #!N #!N Enables a remote DXLink application to set a parameter value in a visual program, while also setting the name of the variable. #!N #!N Syntax #!CForestGreen #!N #!N #!F-adobe-courier-bold-r-normal--18* #!N #!F-adobe-times-bold-r-normal--18* output #!EF = DXLInputNamed( #!F-adobe-times-bold-r-normal--18* name, default #!EF ); #!EF #!N #!N #!EC #!N #!N Inputs #!T,1,91,276,461,646 #!F-adobe-times-medium-r-normal--14* #!F-adobe-times-bold-r-normal--18* #!N TAB Name TAB Type TAB Default TAB Description #!EF #!N TAB name TAB string TAB none TAB name of variable #!N TAB default TAB value, string, object TAB no default TAB default value (overridden by the #!N TAB - TAB - TAB - TAB remote application) #!N TAB - TAB - TAB - TAB #!EF #!N #!N Outputs #!T,1,161,321,646 #!F-adobe-times-medium-r-normal--14* #!F-adobe-times-bold-r-normal--18* #!N TAB Name TAB Type TAB Description #!EF #!N TAB output TAB object TAB the default value or the value sent from a remote application #!N TAB - TAB - TAB #!EF #!N #!N Functional Details #!N #!N This tool receives variable values from a remote application that uses the DXLink library of function calls (see #!Ldxlink,dxall1141 h DXLink Developer's Toolkit #!EL in IBM Visualization Data Explorer Programmer's Reference). The value received from the application is passed as output from the DXLInputNamed tool. #!N #!N This module differs from DXLInput in that the name of the variable is set using the #!F-adobe-times-bold-r-normal--18* name #!EF parameter, rather than using the Notation field of the Configuration Dialog box. This enables the variable name to be passed in via a wire, rather than preset for the module. This allows you to place DXLInputNamed in a macro and have different instances of the macro use different variable names. #!N #!I0 #!N #!N #!I0 #!N #!F-adobe-times-bold-r-normal--18* #!F-adobe-times-bold-r-normal--18* name #!EF #!EF #!I50 #!N is the variable name. This variable is then set by DXLSet... functions of the DXLink development library. #!N #!I0 #!N #!F-adobe-times-bold-r-normal--18* #!F-adobe-times-bold-r-normal--18* default #!EF #!EF #!I50 #!N is the default value for the output of DXLInputNamed. #!I0 #!N #!N #!N #!N If there is no remote application setting the default values, DXLInputNamed will output the value specified by #!F-adobe-times-bold-r-normal--18* default #!EF . If a remote application sets the value, that value overrides #!F-adobe-times-bold-r-normal--18* default #!EF . This parameter provides a mechanism that makes it easier to debug visual programs that are intended to be used and controlled by remote DXLink applications. Note: The #!F-adobe-times-bold-r-normal--18* default #!EF value must be set in the module's configuration dialog box. Any value set by a connection to the output of another tool will #!F-adobe-times-medium-i-normal--18* not #!EF be overridden by a value set by a remote application. #!N #!N See Also #!N #!N #!Ldxlinpt,dxall802 h DXLInput #!EL #!Ldxloutp,dxall804 h DXLOutput #!EL , #!Linput,dxall876 h Input #!EL , #!Loutput,dxall899 h Output #!EL #!N #!N #!Ldxlink,dxall1141 h DXLink Developer's Toolkit #!EL in IBM Visualization Data Explorer Programmer's Reference. #!N #!N #!N #!F-adobe-times-medium-i-normal--18* Next Topic #!EF #!N #!N #!Ldxloutp,dxall804 h DXLOutput #!EL #!N #!F-adobe-times-medium-i-normal--18* #!N
Generated by dwww version 1.15 on Sat Jun 22 12:55:51 CEST 2024.